In the Federal Register published on April 2, 2015, in FR Doc. 2015-06947, make the following correction:
On page 17836: Equation 2 is corrected by removing “13.46” and adding in its place “17.80”. The corrected equation reads as follows:
η
pump,STD= −0.85 * ln(Q
100
%%) 2− 0.38 * ln(Ns) * ln(Q
100
%%) − 11.48 * ln(Ns) 2+ 17.80 * ln(Q
100
%%) + 179.80 * ln (Ns) − (C− 555.6)